I have a Tandberg LTO2 Superloader attached on an Adaptec 39160D and the chg-scsi returns: amtape: could not load slot Can't: read MTE status
Example: $amtape CAPCom update amtape: scanning all 16 slots in tape-changer rack: slot 0: date 20031211 label CAPCom01 amtape: could not load slot Can't: read MTE status $
The thing worked fine with a LSI Megaraid Controller, but I had to change the host :(
The SCSI-Log look a bit confusing to me, because it dies in SCSI_ReadElementStatus which it handled properly some requests before in the log (possibly I'm looking worong, of course)
I'm running Linux with a 1.6.1 kernel, and amanda 2.4.4p2.
Any idea what's wrong?
Here some parts out of the log (it's about 21KB, too long to post I assume).
One of the parts where it seems to work: SCSI_ExecuteCommand : READ ELEMENT STATUS B8 11 00 00 00 02 00 00 00 70 00 00 1074271383:##### STOP DecodeSCSI 1074271383:SCSI_Run Exit 0 1074271384:SCSI_ReadElementStatus : (2) SCSI_Run 0 00 00 00 01 00 00 00 3C 01 80 00 34 00 00 00 34 ...........4...4 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ................ 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ................ 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ................ 00 00 00 00 01 01 09 00 00 00 00 00 00 00 00 00 ................ 49 41 44 37 30 35 4C 31 20 20 20 20 20 20 20 20 IAD705L1........ 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 ................
1074271384:##### STOP SCSI_ReadElementStatus (0)
Part where the log ends: [...] ##### START SenseHandler Ident = [UHDL], function = [generic_changer] ##### START GenericSenseHandler ##### START DecodeSense GenericSenseHandler : Sense Keys Extended Sense ASC 4E ASCQ 00 Sense key 0B Aborted Command Sense2Action START : type(8), ignsense(0), sense(0B), asc(4E), ascq(00) Sense2Action generic start : Sense2Action generic END : match for generic return -> -1/Nothing Found ##### STOP GenericSenseHandler #### STOP SenseHandler 1074271388:SCSI_Run (TestUnitReady) SENSE_ABORT 1074271388:SCSI_ReadElementStatus : (2) SCSI_Run -1 ##### START DecodeSense SCSI_ReadElementStatus :Sense Keys Extended Sense ASC 4E ASCQ 00 Sense key 0B Aborted Command 1074271388:##### STOP SCSI_ReadElementStatus (-1)
-- Thomas Corell CAPCom AG < http://www.capcom.de > Rundeturmstr. 12, 64283 Darmstadt, Germany Phone +49 6151 155 900, Fax +49 6151 155 909