Gardiner Leverett wrote: > I'm having a similar problem someone reported earlier. > I have a subdirectory I'm tying to archive with gtar from > the client "arnold". It failed, so I subdivided it into > smaller pieces. For example, I have about 10 user directories, > so I have a config for the directories a-b, c-d, e-g, h-m, and n-z. > Here's what I get: > > >> -----Original Message----- > >> FAILURE AND STRANGE DUMP SUMMARY: >> arnold /z/workareas-eg lev 0 FAILED [mesg read: Connection reset by > peer] >> arnold /z/workareas-cd lev 0 FAILED [cannot read header: got 0 instead > of 32768] >> arnold /z/workareas-ab lev 0 FAILED [cannot read header: got 0 instead > of 32768] >> arnold /z/workareas-eg lev 0 FAILED [too many dumper retry] >> arnold /z/workareas-eg lev 0 FAILED [cannot read header: got 0 instead > of 32768] >> arnold /z/workareas-cd lev 0 FAILED [too many dumper retry] >> arnold /z/workareas-cd lev 0 FAILED [cannot read header: got 0 instead > of 32768] >> arnold /z/workareas-ab lev 0 FAILED [too many dumper retry] >> arnold /z/workareas-ab lev 0 FAILED [cannot read header: got 0 instead > of 32768] > > And in the dump summary, I get this: > >> DUMP SUMMARY: >> arnold -rkareas-ab 0 FAILED >> arnold -rkareas-cd 0 FAILED >> arnold -rkareas-eg 0 N/A 242 -- N/A N/A N/A N/A PARTIAL >> arnold -rkareas-hm 0 242 32 13.3 25:58 158.9 0:0311598.7 >> arnold -rkareas-nz 0 106 22 21.1 10:58 164.6 0:0211269.6 > >> (brought to you by Amanda version 2.5.0b1-20051205) > > Any idea why I get two of the sub sections, partail of one, and nothing from > the > other two? >
What version of tar are you using? It might be related to what I saw in my recent posting, where tar 1.16 now returns an error code of 1 when a file changes during the run. Previous versions returned a 2 in that case, which I think just caused Amanda to flag it as STRANGE, but a 1 is interpreted as failed, so Amanda retries from the beginning until either it works or you hit 'too many dumper retries', whatever number that is. I haven't seen any replies on what 'PARTIAL' means. Frank -- Frank Smith [EMAIL PROTECTED] Sr. Systems Administrator Voice: 512-374-4673 Hoover's Online Fax: 512-374-4501