Chris,

Enable a user (non-admin) to turn on Filter logs.
Login with the user.
Turn on filter AND active link logs.
Do the thing that produces the error.
Check the log and find the workflow (Active Link or Filter) that does
the SET operation that fails.

That should not take more than a few minutes to setup and a few
minutes to look through the logs.

-- 
Carey Matthew Black
Remedy Skilled Professional (RSP)
ARS = Action Request System(Remedy)

Love, then teach
Solution = People + Process + Tools
Fast, Accurate, Cheap.... Pick two.


On Nov 16, 2007 1:33 PM, Moore, Chris <[EMAIL PROTECTED]> wrote:
> **
>
>
>
> Hey everyone-
>
>
>
> Administrators don't get this error, it must be a filter because I can't log
> it as a non-administrator.
>
>
>
> This is on the form AST:ComputerSystem.  If a non-administrator changes, for
> instance, the serial number and tries to save, they get this error.  The
> field DataSet Name is not on the form and when I did it as an administrator
> and logged it, that field did not appear in the log.
>
>
>
> Does anyone know a quick way I can find which form contains that field?
>
>
>
> Thanks,
>
> Chris

_______________________________________________________________________________
UNSUBSCRIBE or access ARSlist Archives at www.arslist.org
Platinum Sponsor: www.rmsportal.com ARSlist: "Where the Answers Are"

Reply via email to