Bill,
 
 
Can you change the scanner to throw a <CR> after the Bar Code scan?
 
Where is Phil Bautista ... this is his specialty !!
 
Regards...Gidd
 
 
 


  _____  

From: Action Request System discussion list(ARSList)
[mailto:[email protected]] On Behalf Of Bill Myers
Sent: Friday, October 09, 2009 6:52 AM
To: [email protected]
Subject: Re: Mid-tier and Scanners


** 

The application is for issuing and receiving product orders.  The current
design has a control panel that the user initially accesses.  On the control
panel are three buttons.  One button takes the user to another form for
issuing orders.  One button takes the user to a form for receiving orders.
The third button logs the user out of the application.

 

On the issue order form, the user will scan a barcode into a field and
submit the order to Remedy.  This form also has a table that shows the
orders issued in the last 10 minutes.  On the receiving form, the user will
again scan a barcode into a field, upon scan the order quantity and expected
delivery date are pulled into the form from the order record created
previously.  The user will be able to adjust the quantity and date, if
necessary , and then submit the receipt to Remedy.

 

Finally, the user should have the ability to print a receipt label that will
then accompany the product as it is processed.

 

I have attempted to fire active links on every possible firing condition.
Return, button, gain focus, etc.  Nothing has worked.  We have attempted
various key combinations and configurations with the scanner as well.
Again, the application just doesn't seem to recognize any input from the
scanner.  I am focusing on the logout item first, figuring if I can get that
to work, the other items should work as well.

 

Hopefully, this will be sufficient details.  If not, let me know.

 

From: Action Request System discussion list(ARSList)
[mailto:[email protected]] On Behalf Of Joel D. Sender
Sent: Thursday, October 08, 2009 7:37 PM
To: [email protected]
Subject: Re: Mid-tier and Scanners

 

** ** 

Need some details: 

Are you using active links that fire on 'return' ?  (scanner appends a <CR>
to each scan).

Are the active links not firing on MT?

 

Joel

*******************************************

Joel Sender

 

-----Original Message-----
From: Action Request System discussion list(ARSList)
[mailto:[email protected]]on Behalf Of Bill Myers
Sent: Thursday, October 08, 2009 2:25 PM
To: [email protected]
Subject: Re: Mid-tier and Scanners

 

Really basic stuff.  Enter data into 2 or 3 fields, submit the requests,
change from one form to another and logout.  There may be printing down the
road.

 

From: Action Request System discussion list(ARSList)
[mailto:[email protected]] On Behalf Of Chowdhury, Tauf
Sent: Thursday, October 08, 2009 5:20 PM
To: [email protected]
Subject: Re: Mid-tier and Scanners

 

** 

What kind of interaction are you looking for? Are you looking to just submit
requests or do you want to encompass all functions such as Query, Submit,
Modify, Delete? 

 

Tauf Chowdhury 

Analyst, Service Management

Office: 631.858.7765

Mobile:646.483.2779

 

 

 

From: Action Request System discussion list(ARSList)
[mailto:[email protected]] On Behalf Of Bill Myers
Sent: Thursday, October 08, 2009 5:14 PM
To: [email protected]
Subject: Mid-tier and Scanners

 

** 

Is it possible to have a scanner interact directly with a Remedy 7.1
mid-tier application.  The scanner we are using is a Symbol running IE on
WinCE 5.01.  We have the mid-tier application on the scanner display, but,
can't get any workflow to fire.  So far, we've not discovered a scanner
configuration or workflow setting that will work.

 

I've searched the archives and have seen where this subject is brought up,
but, no answer is provided.  At least that I could find.  BMC support has
been unable to provide any information.  Hopefully, the answer doesn't
involve more software.

 

ARS 7.1 patch 2 on Windows 2003 server

Oracle 10g on Linux

Mid-tier 7.1 - Apache/Tomcat on Windows 2003 server

 

Thanks!

 

Bill Myers

Remedy Developer

Datacraft Solutions, Inc.

[email protected]

(p) 919-667-9804

(f) 919-682-5986

_Platinum Sponsor: [email protected] ARSlist: "Where the Answers
Are"_ 

  _____  

This e-mail and its attachments may contain Forest Laboratories, Inc.
proprietary information that is privileged, confidential or subject to
copyright belonging to Forest Laboratories, Inc. This e-mail is intended
solely for the use of the individual or entity to which it is addressed. If
you are not the intended recipient of this e-mail, or the employee or agent
responsible for delivering this e-mail to the intended recipient, you are
hereby notified that any dissemination, distribution, copying or action
taken in relation to the contents of and attachments to this e-mail is
strictly prohibited and may be unlawful. If you have received this e-mail in
error, please notify the sender immediately and permanently delete the
original and any copy of this e-mail and any printout.

_Platinum Sponsor: [email protected] ARSlist: "Where the Answers
Are"_ 

_Platinum Sponsor: [email protected] ARSlist: "Where the Answers
Are"_ _Platinum Sponsor: [email protected] ARSlist: "Where the
Answers Are"_

_Platinum Sponsor: [email protected] ARSlist: "Where the Answers
Are"_ 

_______________________________________________________________________________
UNSUBSCRIBE or access ARSlist Archives at www.arslist.org
Platinum Sponsor:[email protected] ARSlist: "Where the Answers Are"

Reply via email to