Dear List
Hoping some one will be able to help me in this
Since Wednesday this has happened at least 3-4  times... once i restart the 
server the everything is normal and it goes on to work till this issue occurs 
again.

i have disabled Allow Disqualified search option in the server info form today 
morning and waiting to see if this issue occurs again. Its 1 hr gone but the 
issue has not reproduced it self.

Fri Feb 18 08:22:35 2011 390635: AR System server terminated when a 
signal/exception was received by the server (ARNOTE 20)
Fri Feb 18 08:22:35 2011     0xc0000005
Fri Feb 18 08:22:35 2011 390635: AR System server terminated -- fatal error 
encountered (ARNOTE 21)
Fri Feb 18 08:22:51 2011 390635: AR System server terminated when a 
signal/exception was received by the server (ARNOTE 20)
Fri Feb 18 08:22:51 2011
   Thread Id: 1908
   Version: 6.03.00 Patch 023 200709012215 Sep 1 2007 23:35:38
   Code: c0000005
   Operation: read
   Access Addr: 00000000
   Stack Begin:
      Addr: 0040D369
      Addr: 4C2D5053
   Stack End:

Fri Feb 18 08:22:51 2011  390635 : AR System server terminated when a 
signal/exception was received by the server (ARNOTE 20)
Fri Feb 18 08:22:51 2011     0xc0000005
Fri Feb 18 08:22:51 2011  390635 : AR System server terminated -- fatal error 
encountered (ARNOTE 21)
Fri Feb 18 08:24:53 2011  BRIE : Cannot open catalog; Message number = 92 
(bomw040a)  ARERR - 92

I am on arsystem 6.3 ITSM 5.5 patch 23
Nothing on the armonitor side.

With Best Regards
Rajesh Nair
Siemens IT Solutions and Services GmbH
SIS GO GAA
HCC 247 Park, Hincon House,
Tower-A, 8-10th floor, LBS Road,
Vikhroli (West), Mumbai 400 083, INDIA
Desk   : +91 22 3937 2027
mailto:[email protected]

Share your thoughts with us:
[cid:[email protected]]<http://twitter.com/SiemensAppMan>        
[cid:[email protected]] 
<http://www.linkedin.com/groups?gid=2865118>         
<https://www.xing.com/net/applicationmngt/>   
[cid:[email protected]] 
<http://www.competence-site.de/application-management>    
[cid:[email protected]] 
<http://www.slideshare.net/ApplicationManagement>


Siemens IT Solutions and Services GmbH: Managing Directors: Christian Oecking, 
Martin Bentler, Rainer-Christian Koppitz, Thomas Zimmermann; Registered Office: 
Munich, Germany; Commercial Register: Munich, HRB 184933

Important notice: This e-mail and any attachment thereof contain corporate 
proprietary information. If you have received it by mistake, please notify us 
immediately by reply e-mail and delete this e-mail and its attachments from 
your system. Thank you.


_______________________________________________________________________________
UNSUBSCRIBE or access ARSlist Archives at www.arslist.org
attend wwrug11 www.wwrug.com ARSList: "Where the Answers Are"

<<inline: image001.jpg>>

<<inline: image002.jpg>>

<<inline: image003.jpg>>

<<inline: image004.jpg>>

Reply via email to