On Thu, 24 Jun 2010 11:53:40 -0500 Chris Craddock <[email protected]> wrote:
:>> :>> Got a data exception with reason code 7 for an STD instruction in an :>> SRB routine : :>> 00000000 *PGM 007 078C2000 D43615B6 00040007 00000000 :>> The instruction STD FR10,... :>> As far as I see , the control reg 0 , bit 45 (AFP control) is on . :>> (It is a z9 S07) :>An SRB routine running in PSW key 8?!? WTF? Nothing at all wrong with that. It knows that the areas that it needs to modify are in key8. It is a quite bad practice to run in key0 when it is not needed. All sorts of bad overlays can happen. -- Binyamin Dissen <[email protected]> http://www.dissensoftware.com Director, Dissen Software, Bar & Grill - Israel Should you use the mailblocks package and expect a response from me, you should preauthorize the dissensoftware.com domain. I very rarely bother responding to challenge/response systems, especially those from irresponsible companies.