[email protected] wrote:
Im executing 5 Instructions and then I force an Abend.
I load the address of a storage area into Register 1 nd verify it by the 
presence of an eye-catcher.
After executing the 5 instructions below; I expect the area Labeled "LOCLCOMM" 
to contain a copy of the eye-catcher that Register 1 is pointing to. However after 
execiting the 5 instructions the area LOCLCOMM contains 256 Binary zeroes ???
.
.
There is No Multi Tasking as this is a single TCB program.
.
.
L R1,ANCHOR1@ Storage Anchor Address CLC STATIC_EYE,00(R1) Valid Eye Catcher JNE NO_STATIC_EYE NO Eye-Catcher * LARL R14,LOCLCOMM DEBUG MVC 00(16,R14),00(R1) DEBUG ABEND 444,DUMP,STEP DEBUG *
*
*
DS 0D Alignment DC CL8'LOCLCOMM' Eye Catcher LOCLCOMM DS CL256 DC CL12'LOCLCOMMEND ' Eye Catcher ORG , .
.
So what Am I missing here ? Can someone point out my mistake ?
.
.
Paul
What exactly is in R1?

Bob

Reply via email to