For LOC vs LOCR, at least those are two different machine formats.  I can 
understand the mask being placed differently in different machine formats.

In some cases I noticed that newer instructions (e.g., the "on condition" 
additions from the Load/store-on-condition facility 1/2 that use machine format 
RSY-b) use a different HLASM operand order than earlier RSY-b format 
instructions.  The newer on-condition instructions use HLASM order 1,2,3 while 
the earlier ones (like ICMH/ICMY/STCMH/STCMY) use HLASM order 1,3,2 and the 
machine operand order is 1,3,2. 

Peter

-----Original Message-----
From: IBM Mainframe Assembler List [mailto:[email protected]] On 
Behalf Of [email protected]
Sent: Friday, March 27, 2015 5:40 AM
To: [email protected]
Subject: Re: HLASM operand order vs. instruction operand order

I do have the same curiosity- (I did notice the mask jumping from left
to right nibble even within one family, see LOC vs LOCR) . 

Dan Greiner's answer was: no specific reason.
-- 