>From Bernd Oppolzer: >If you specify this global "baseless" parameter (specified at the >startup macro and controlling >all SP macros and the lightweight CALL and PROC macros), there is >only one base register >which covers the area after ENDPROC, allowing for up to 4 k of local >static variables
FWIW, if you can use the long-displacement instuctions then you can access a pretty much unlimited amount of local static with one base register. Best regards, Steve Hobson CICS Strategy, HLASM Development, Master Inventor IBM United Kingdom Limited, Room A3038 MP189 Hursley Park, Winchester, Hampshire. SO21 2JN Phone: +44 (0) 1962 81 6894 (Internal: 246894) Je me presse de rire de tout, de peur d'ĂȘtre obligĂ© d'en pleurer Unless stated otherwise above: IBM United Kingdom Limited - Registered in England and Wales with number 741598. Registered office: PO Box 41, North Harbour, Portsmouth, Hampshire PO6 3AU