On 2018-12-29, at 09:47:08, Paul Gilmartin wrote:

> In: MVS Interactive Problem Control System (IPCS) Customization
> Version 2 Release 3  SA23-1383-30
> 
> I read:
> TOD Clock Service
>    The time-of-day (TOD) clock service provides a caller, including your exit 
> routine,
>    with a TOD clock image. In the clock image, bit 0 is set on to allow the 
> service to
>    handle values from May 11,1971, at 11:56:53.685248 to January 25, 2114, at
>    11:50:41.055743.
>  
I was running a similar thread on IBM-MAIN.  An IBM employee agrees
this is an error and noticed several others, and has offered an RCF.

-- gil