"IBM Mainframe Assembler List" <[email protected]> wrote on
12/04/2023 04:00:38 PM:
> Does the z/VSE linkage editor support re-linking an
> existing module replacing a few sections? To do
> that on z/OS an ORDER statement may be needed.
Existing objects can be re-linked (with/without some section
selections and/or with patches), but I don't think the linkage editor will
do anything with an existing load module except replace it entirely -- if
that is what you meant. These are the available statements on z/VSE.
ACTION ...
PHASE name,origin<,...>
MODE {AMODE(...)|RMODE(...)}<,{RMODE(...)|AMODE(...)}>
INCLUDE <objectname><,(sectionlist)>
REP address ...
ENTRY <entrypoint>
Sincerely,
Dave Clark
--