"IBM Mainframe Assembler List" <ASSEMBLER-LIST@LISTSERV.UGA.EDU> wrote on 
12/04/2023 04:00:38 PM:
> Does the z/VSE linkage editor support re-linking an
> existing module replacing a few sections?  To do
> that on z/OS an ORDER statement may be needed.


        Existing objects can be re-linked (with/without some section 
selections and/or with patches), but I don't think the linkage editor will 
do anything with an existing load module except replace it entirely -- if 
that is what you meant.  These are the available statements on z/VSE.

ACTION  ...
PHASE   name,origin<,...>
MODE    {AMODE(...)|RMODE(...)}<,{RMODE(...)|AMODE(...)}>
INCLUDE <objectname><,(sectionlist)>
 REP  address ...
ENTRY   <entrypoint>


Sincerely,

Dave Clark
-- 
int.ext: 91078
direct: (937) 531-6378
home: (937) 751-3300

Winsupply Group Services
3110 Kettering Boulevard
Dayton, Ohio  45439  USA
(937) 294-5331




*********************************************************************************************
This email message and any attachments is for use only by the named 
addressee(s) and may contain confidential, privileged and/or proprietary 
information. If you have received this message in error, please 
immediately notify the sender and delete and destroy the message and all 
copies. All unauthorized direct or indirect use or disclosure of this 
message is strictly prohibited. No right to confidentiality or privilege 
is waived or lost by any error in transmission. 
*********************************************************************************************

Reply via email to