You have a RED alarm on the link. Check also " head /proc/zaptel/1"
So either you have wrong framing, no CRC4, or a diffrent timing or the circuit is disconnected. Martin On Fri, 13 Jun 2003, Jorge wrote: > Hi, > > I have an E100P card. > > My zaptel.conf is: > span=1,0,0,cas,ami,crc4 > bchan=1-2 > dchan=3 > loadzone = us > defaultzone=us > > after execute ztcfg red led becomes blinking, why ? > > Anybody known the led's table of thruth ? > > Regards, > > Jorge Castellet > INFALSYS S.L. > _______________________________________________ > Asterisk-Users mailing list > [EMAIL PROTECTED] > http://lists.digium.com/mailman/listinfo/asterisk-users > _______________________________________________ Asterisk-Users mailing list [EMAIL PROTECTED] http://lists.digium.com/mailman/listinfo/asterisk-users