You have a RED alarm on the link.
Check also " head /proc/zaptel/1"

So either you have wrong framing, no CRC4, or a diffrent timing or the
circuit is disconnected.

Martin

On Fri, 13 Jun 2003, Jorge wrote:

> Hi,
>
> I have an E100P card.
>
> My zaptel.conf is:
> span=1,0,0,cas,ami,crc4
> bchan=1-2
> dchan=3
> loadzone = us
> defaultzone=us
>
> after execute ztcfg red led becomes blinking, why ?
>
> Anybody known the led's table of thruth ?
>
> Regards,
>
> Jorge Castellet
> INFALSYS S.L.
> _______________________________________________
> Asterisk-Users mailing list
> [EMAIL PROTECTED]
> http://lists.digium.com/mailman/listinfo/asterisk-users
>

_______________________________________________
Asterisk-Users mailing list
[EMAIL PROTECTED]
http://lists.digium.com/mailman/listinfo/asterisk-users

Reply via email to