Chris Mason (Lists) wrote:
After rebooting the SPA-3000, the internal users of calls routed through
the FXO interface hear pretty bad echo. This persists for days, maybe
more than a week. At some point, the echo goes away.
This is a known problem with the spa3k-3.1.5b firmware, I have made them
aware of it and hopefully they are working on a fix.
I'm also seeing this with
Software Version: 2.0.13(GWg)
Hardware Version: 2.0.1(7567)
I also have the SPA to PSTN gain down to -3 and PSTN to SPA to +3
(I've been having trouble hearing the people I've called). The
echo was so bad at one point I was hearing multiple echoes.
--
Linux Home Automation Neil Cherry [EMAIL PROTECTED]
http://home.comcast.net/~ncherry/ (Text only)
http://hcs.sourceforge.net/ (HCS II)
http://linuxha.blogspot.com/ My HA Blog