Lincoln Zuljewic Silva wrote:
Yes, I saw that...I just don't know what do to anymore. The framing and protocol between machines are the same and the pri signaling is ok in both machines.
Not that this is it, but you have: signalling=pri_net It should probably be pri_cpe, net being the PBX. What PBX is it? Ours it a Avaya Definity G3R. Doug -- Ben Franklin quote: "Those who would give up Essential Liberty to purchase a little Temporary Safety, deserve neither Liberty nor Safety." _______________________________________________ --Bandwidth and Colocation provided by Easynews.com -- asterisk-users mailing list To UNSUBSCRIBE or update options visit: http://lists.digium.com/mailman/listinfo/asterisk-users
