Lincoln Zuljewic Silva wrote:
Yes, I saw that...I just don't know what do to anymore. The framing and protocol between machines are the same and the pri signaling is ok in both machines.

Not that this is it, but you have:

signalling=pri_net

It should probably be pri_cpe, net being the PBX.

What PBX is it?

Ours it a Avaya Definity G3R.

Doug

--