On Thu, 2007-09-20 at 13:20 -0400, Brian Alexander wrote:
> ====
> Machine 1 experiences almost the same behavior on its span. The only
> differance I am noticing is that instead of the S-frame error I get
> the following notice:
> 
>   chan_zap.c:8457 pri_dchannel: PRI got event: HDLC Bad FCS (8) on
> Primary D-channel of span 1 

I'd look at your wiring, as an HDLC error like that is usually an
indication of some type of a problem at the physical layer.  


-- 
Jared Smith
Community Relations Manager
Digium, Inc.


_______________________________________________

Sign up now for AstriCon 2007!  September 25-28th.  http://www.astricon.net/ 

--Bandwidth and Colocation Provided by http://www.api-digital.com--

asterisk-users mailing list
To UNSUBSCRIBE or update options visit:
   http://lists.digium.com/mailman/listinfo/asterisk-users