Maxim Litnitskiy wrote:

> FALC version: 00000005, Board ID: 09

The board ID switch (the rotary switch on the board) is set to 9 (nine).
  If you are going to have the switches set to anything other than zero,
there must be at least one board with it set to zero, then one set to
one, then one set to two, etc. Skipping numbers causes boards to be
ignored by the driver at startup time, even though they were located.

-- 
Kevin P. Fleming
Digium, Inc. | Director of Software Technologies
445 Jan Davis Drive NW - Huntsville, AL 35806 - USA
skype: kpfleming | jabber: [email protected]
Check us out at www.digium.com & www.asterisk.org