Matt Florell wrote: > If you want to be able to set Master timing you will have to use > Sangoma cards, they allow you force the timing in the wanrouter > configuration. I have done extensive testing with crossover T1/E1/PRIs
I don't believe this is true; we use Digium cards connected back-to-back to each other, with one providing the span timing (clock) all the time. This is a very common configuration and works fine. To set a Zaptel/DAHDI card to provide span timing, just set all the spans on it to 'zero' as the priority for timing source; when none of the span clocks are the timing source, the onboard clock on the card will be the timing source. -- Kevin P. Fleming Digium, Inc. | Director of Software Technologies 445 Jan Davis Drive NW - Huntsville, AL 35806 - USA skype: kpfleming | jabber: [email protected] Check us out at www.digium.com & www.asterisk.org _______________________________________________ -- Bandwidth and Colocation Provided by http://www.api-digital.com -- asterisk-users mailing list To UNSUBSCRIBE or update options visit: http://lists.digium.com/mailman/listinfo/asterisk-users