Olivier wrote: > What if using a patch cord from port to another ? > Would you still value to zero each span timing priority or would you set > one end to 0 and the other to 1 ?
For connecting spans on a single card to each other, all the spans should be set to '0'; there is no need to use a recovered clock for any spans when they are all on the same card and using the same clock for transmission. -- Kevin P. Fleming Digium, Inc. | Director of Software Technologies 445 Jan Davis Drive NW - Huntsville, AL 35806 - USA skype: kpfleming | jabber: [email protected] Check us out at www.digium.com & www.asterisk.org _______________________________________________ -- Bandwidth and Colocation Provided by http://www.api-digital.com -- asterisk-users mailing list To UNSUBSCRIBE or update options visit: http://lists.digium.com/mailman/listinfo/asterisk-users