Olivier wrote:

> What if using a patch cord from port to another ?
> Would you still value to zero each span timing priority or would you set
> one end to 0 and the other to 1 ?

For connecting spans on a single card to each other, all the spans
should be set to '0'; there is no need to use a recovered clock for any
spans when they are all on the same card and using the same clock for
transmission.

-- 
Kevin P. Fleming
Digium, Inc. | Director of Software Technologies
445 Jan Davis Drive NW - Huntsville, AL 35806 - USA
skype: kpfleming | jabber: [email protected]