On Thu, 28 Oct 2004, Ashish Shinde wrote: > I need to interface the wildcard t100p with the Simens HiPath 3000 > PBX's T1 interface. I tried all the possible options for framing and > signalling, but could get the card to interface correctly. The LED on > the card always shows error. I tried connecting the PBX with a cross > as well as straight T1 cable. > I would be really grateful if someone can help me in this regard.
Who supplies the clocking? If neither end supplies it there will be problems. Did you use a T1 cross over and not an ethernet cross over? Do you know / have you set the framing and coding correct for the zaptel line in /etc/zaptel.conf? Have you loaded the zaptel module? Sucessfully? Have you run ztcfg? Peter _______________________________________________ Asterisk-Users mailing list [EMAIL PROTECTED] http://lists.digium.com/mailman/listinfo/asterisk-users To UNSUBSCRIBE or update options visit: http://lists.digium.com/mailman/listinfo/asterisk-users