I really don't know who supplies the clocking. How to find that out? I did use a T1 cross - over cable and I tried all possible options for framing and coding in zaptel.conf. Tried ztcfg too. It doesn't complain. Is there any way to find out the framing and coding
On Thu, 28 Oct 2004 11:07:01 +0200 (CEST), Peter Svensson <[EMAIL PROTECTED]> wrote: > On Thu, 28 Oct 2004, Ashish Shinde wrote: > > > > > I need to interface the wildcard t100p with the Simens HiPath 3000 > > PBX's T1 interface. I tried all the possible options for framing and > > signalling, but could get the card to interface correctly. The LED on > > the card always shows error. I tried connecting the PBX with a cross > > as well as straight T1 cable. > > I would be really grateful if someone can help me in this regard. > > Who supplies the clocking? If neither end supplies it there will be > problems. > > Did you use a T1 cross over and not an ethernet cross over? > > Do you know / have you set the framing and coding correct for the zaptel > line in /etc/zaptel.conf? > > Have you loaded the zaptel module? Sucessfully? > > Have you run ztcfg? > > Peter > > _______________________________________________ Asterisk-Users mailing list [EMAIL PROTECTED] http://lists.digium.com/mailman/listinfo/asterisk-users To UNSUBSCRIBE or update options visit: http://lists.digium.com/mailman/listinfo/asterisk-users