Yes. I've tried: - ztcfg - rmmod the wct4xxp module and zaptel and modprob'ing again - rebooting the server. No matter what I do, the second card is always "internally clocked". The E1 I have plugged into that board is good. It can clock the first card just fine. This is my complete zaptel.conf, just for reference: # E1 ISDN PRI. span=1,1,0,ccs,hdb3 bchan=1-15 dchan=16 bchan=17-31 # E1 R2 span=2,2,0,cas,hdb3 cas=32-46:1101 cas=48-62:1101 # E1 ISDN PRI span=3,0,0,ccs,hdb3 bchan=63-77 dchan=78 bchan=79-93 # T1 Channel bank. span=4,0,0,esf,b8zs fxsks=94-101 fxoks=102-117 # E1 ISDN PRI. Same carrier as span 1. Line can be exchanged with span 1 and all is OK. span=5,1,0,ccs,hdb3 bchan=118-132 dchan=133 bchan=134-148 # E1 Unused. span=6,0,0,ccs,hdb3 unused=149-163 unused=164 unused=165-179 # E1 Unused span=7,0,0,ccs,hdb3 unused=180-194 unused=195 unused=196-210 # T1 Channel bank. span=8,0,0,esf,b8zs fxoks=211-234 Fernando Rich Adamson wrote:
|
_______________________________________________ Asterisk-Users mailing list [EMAIL PROTECTED] http://lists.digium.com/mailman/listinfo/asterisk-users To UNSUBSCRIBE or update options visit: http://lists.digium.com/mailman/listinfo/asterisk-users