Trevor Peirce wrote:

Anyhow, they are seeing the RELEASE COMPLETE message with cause code 1, however the tech told me they expect a PROGRESS indicator with a value between 1 and 10.

Okay after printing off a dozen pages and taking up tons of floor space I think I may have figured this out... but this being my first day in PRI-language I'd appreciate some feed back if I'm on the right track.


First, I am seeing

< SETUP
> CALL PROCEEDING
< FACILITY (w/ CID Name)
> RELEASE COMPLETE (Cause: 1)

From what I understand from Q.931's figure A.2, is that the CALL PROCEEDING should *not* be sent to do this... and if it is we've got to addto the dialog slightly

< SETUP
> CALL PROCEEDING
< FACILITY (w/ CID Name)
> DISCONNECT (Cause: 1)
< RELEASE
> RELEASE COMPLETE (Cause: 1)

Someone please let me know if I'm talking nonsense or if I am going somewhere with this...

Many thanks,
Trevor Peirce