Trevor Peirce wrote:
Anyhow, they are seeing the RELEASE COMPLETE message with cause code 1, however the tech told me they expect a PROGRESS indicator with a value between 1 and 10.
Okay after printing off a dozen pages and taking up tons of floor space I think I may have figured this out... but this being my first day in PRI-language I'd appreciate some feed back if I'm on the right track.
First, I am seeing
< SETUP > CALL PROCEEDING < FACILITY (w/ CID Name) > RELEASE COMPLETE (Cause: 1)
From what I understand from Q.931's figure A.2, is that the CALL PROCEEDING should *not* be sent to do this... and if it is we've got to addto the dialog slightly
< SETUP > CALL PROCEEDING < FACILITY (w/ CID Name) > DISCONNECT (Cause: 1) < RELEASE > RELEASE COMPLETE (Cause: 1)
Someone please let me know if I'm talking nonsense or if I am going somewhere with this...
Many thanks, Trevor Peirce _______________________________________________ Asterisk-Users mailing list [email protected] http://lists.digium.com/mailman/listinfo/asterisk-users To UNSUBSCRIBE or update options visit: http://lists.digium.com/mailman/listinfo/asterisk-users
