Chad,

THANK YOU for this! We have a customer who has been experiencing the
same issue for two months now. Rebooting gets them back online, but
that's a terrible fix, and not something easily explained the third or
fourth time it has to be done. 

I didn't know that Beta12 was out, and Sangoma has yet to issue me a fix
for the problem since I last brought it to them. I just spoke with them,
and I'm told this will clear the issue right up. Thanks for bringing
this to my attention!

Cheers,
Alex

___________________________________________ 
Alex Robar,  Technical Support,   GearyTech Inc.
 
3075 Fourteenth Avenue, Unit 3, Markham, Ontario L3R 0G9
Markham: 905-513-8000  x 223              Fax: 905-513-8040
Toronto: 416-226-3614                  Toll Free: 888-890-3499
[EMAIL PROTECTED]                 www.gearytech.com
 
Strategic management of technology for business. 

-----Original Message-----
From: Chad Osmond [mailto:[EMAIL PROTECTED] 
Sent: Wednesday, November 15, 2006 3:07 PM
To: [email protected]
Subject: [on-asterisk] Sangoma A200's in Production? Patch to Beta12....

I just got back from a client with a 12 port A200...

It seems that one of the FXO groups stopped detecting rings, and a quick
call to Sangoma informed me that there is a bug in everything under
beta12.
Registers get full on the card, and then won't detect rings. It lasted
about 3 weeks before dropping calls.

I was running Beta7 in production for a few weeks, fairly high volume,
and this has been the first glitch.

On another note, the A200's Echo is top notch.. I have had zero echo on
the calls.
Overall, it's a fantastic product, that I would easily use again.