Now that I got the HT488 working correctly (tnx for the help 2 weeks ago), I'm having reliability issues with it; it's either not noticing call disconnect or it's locking up. Result: not answering incoming nor allowing outgoing. Having to reboot it every two days is a PITA, though I could automate that using gsutil and cron to reboot it every morning during the wee hours (it still accepts web commands, thankfully).

Has anybody:
1) Had hands-on experience with the FXO port of this device's replacement, the Grandstream HT-503
        http://www.grandstream.com/ht503.html
It's in a new case so it might be an all-new hardware base, or it might just be tarted up a little (at least it claims to support incoming callerid on FXO, which the 488 never did and never will).

2) Knowledge of any other low-cost SIP (or IAX2) FXO ATA? I know there are lots of FXS ATAs but I needs FXO. Don't need something with a lot of ports.

Any actual experience with the FXO port of SPA-3102? This thread http://forums.whirlpool.net.au/forum-replies-archive.cfm/571623.html claims they have echo problems on the FXO port, but that's from 18 months ago.

Not interested in WRTG54 stuff as I don't need a router etc., Asterisk is already running happily on a small Arm-based computer.

Thanks

---------------------------------------------------------------------
To unsubscribe, e-mail: [EMAIL PROTECTED]
For additional commands, e-mail: [EMAIL PROTECTED]

Reply via email to