[EMAIL PROTECTED] пишет:
> Hello Andrey,
>
>   
>> I  am do that I want :)  The fist, that I saw it was sendfile on nginx 
>> doesn't work.
>>     
>
> I guess you forgot applying splice-2.6.23.patch and enabling
> CONFIG_AUFS_SPLICE_PATCH (if your kernel is linux-2.6.23 or later).
>   
Thank for patch :)
> (from aufs README)
> - splice-2.6.23.patch
>   For linux-2.6.23 and later.
>   When you use splice(2) (sendfile(2) in linux-2.6.23 and later), or
>   loopback-mount an fs-image file in aufs, this patch is
>   required. Aufs doesn't support splice(2) in linux-2.6.22 and
>   earlier.
>   If unionfs patch v2.3 or later is applied to your kernel, then you
>   don't need this patch.
>
>
> I thought thar raid5 can recover data after ONE drive failure. Is what
> you have experienced a bug in software raid?
>   

It was software RAID, when I did reshape from 8 disk to 10 my server was 
reboot and then I saw dmesg, where was written  that  4 of 10 disks are 
fail.

-- 
WBR, Andrey Vasilishin CDIG1-UANIC, CDIG1-RIPE


-------------------------------------------------------------------------