Brian Dean <[EMAIL PROTECTED]> wrote: > > OK, well, feeling a little dangerous, I just set the SCK period down > to 1.1 us - the fastest allowed, and that dropped the read time down > to 27 seconds - much more appetizing. Is it safe to do this? I did > do a program and verify and it checked out OK. >
As long as the internal clock frequency of the target AVR is greater or equal to four times the SCK frequency, I think you should be okay. I ran into SCK frequency problems on my initial programming attempts with the mega48. The internal oscillator of the mega48 runs at 8 MHz, but the clk divide by 8 fuse defaults to on. Thus I have to set the SCK period to >= 4 us for unprogrammed parts. galen _______________________________________________ avrdude-dev mailing list [email protected] http://lists.nongnu.org/mailman/listinfo/avrdude-dev