Bob Paddock <[EMAIL PROTECTED]> wrote: > > I fired up a old STK500 board on my Gentoo Linux box with > a new, fresh from DigiKey, Mega168. I am getting random > signature and fuse read failures. Does anyone have any suggestions? > > I did see the bug report about the unused efuse bits in the m168, but what > I'm seeing is happening in the other fuses and signature as well. > > Clock to fast maybe? > > SCK period : 1.1 us
If the fuses are in the factory default state, then SCK is too fast. The mega168 is running at 1MHz (8 MHz internal osc with 1/8 prescaler). SCK frequency needs to be less than or equal to one quarter of the system clock. Try setting SCK period to 4.4 us. galen _______________________________________________ avrdude-dev mailing list [email protected] http://lists.nongnu.org/mailman/listinfo/avrdude-dev