I want it is so, but in fact during job my library very often wants to
clean drives(LTO-6).
Without auto cleaning library fails job with tape errors.
Consider a admin job where the drive is cleaned. I'm very confused by
the library needing to clean so often.
--
Dan Langille
http://langille.org/
On Nov 10, 2014, at 7:45 AM, Andrey Chebotarev <a...@525.su
<mailto:a...@525.su>> wrote:
Ok, may be there is another solution.
Let's put everything in one place:
I have very long jobs, which spend 30-40 cartridges per one.
I have library which have to be configured with auto cleaning.
During running job after several cartridges filled, say 10, library
wants to clean tape and does it automatically. Cleaning takes more
than 5 minutes.
Meanwhile bacula is trying to load new cartridges and after 5 minutes
fails.
What is the best solution of my issue?
I wanted to change the code by myself. I just wanted to know where
is in code place where defined 5 minutes timeout.
On Nov 10, 2014, at 3:33 AM, Andrey Chebotarev <a...@525.su
<mailto:a...@525.su>> wrote:
Hi.
It's in devel because the question about editing sources, but not
about configuration.
And I think solve the question could only developer.
The conclusion to change the code is premature.
On Nov 4, 2014, at 6:55 AM, Andrey Chebotarev <a...@525.su
<mailto:a...@525.su>> wrote:
Hi guys.
I use bacula 5.2.13 with IBM TS3200 library.
Periodically I face problem with load slot time out. In logs it
looks lilke:
/22-Sep 00:35 baculasrv-dir JobId 10471: Recycled volume
"220AAAL6"//
//22-Sep 00:35 baculasrv-sd JobId 10471: 3304 Issuing
autochanger "load slot 1, drive 1" command.//
//22-Sep 00:40 baculasrv-sd JobId 10471: Fatal error: 3992 Bad
autochanger "load slot 1, drive 1": ERR=Child died from signal
15: Termination.//
//Results=Program killed by Bacula (timeout)//
//22-Sep 00:32 sqcompose-fd JobId 10471: Fatal error:
backup.c:1019 Network send error to SD.//
/
As I understood, bacula tries to load slot for 5 minutes and if
it's not successful stops job.
I started investigation why bacula sometimes doesn't manage to
load slot in 5 minutes and find out library stops responding to
commands and starts cleaning drive procedure which takes more
than 5 minutes(Library was configured to clean drive automatically)
So how can I solve the problem?
I've found place in mtx-changer script where declared 300
seconds to wait. I've increased it value to 1800 seconds. Is it
only place or I have to change somthing else in sources?
Hi everybody.
Increasing timeout in mtx-changer script hasn't helped, I have
the same issue. Where in sources I can increase timeout to 30
minutes?
I don’t see why this is on devel It should be on users, which is
cc’d here.
------------------------------------------------------------------------------
_______________________________________________
Bacula-devel mailing list
Bacula-devel@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/bacula-devel
------------------------------------------------------------------------------
_______________________________________________
Bacula-devel mailing list
Bacula-devel@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/bacula-devel