Hi.
It's in devel because the question about editing sources, but not about
configuration.
And I think solve the question could only developer.
On Nov 4, 2014, at 6:55 AM, Andrey Chebotarev <a...@525.su
<mailto:a...@525.su>> wrote:
Hi guys.
I use bacula 5.2.13 with IBM TS3200 library.
Periodically I face problem with load slot time out. In logs it
looks lilke:
/22-Sep 00:35 baculasrv-dir JobId 10471: Recycled volume "220AAAL6"//
//22-Sep 00:35 baculasrv-sd JobId 10471: 3304 Issuing autochanger
"load slot 1, drive 1" command.//
//22-Sep 00:40 baculasrv-sd JobId 10471: Fatal error: 3992 Bad
autochanger "load slot 1, drive 1": ERR=Child died from signal 15:
Termination.//
//Results=Program killed by Bacula (timeout)//
//22-Sep 00:32 sqcompose-fd JobId 10471: Fatal error: backup.c:1019
Network send error to SD.//
/
As I understood, bacula tries to load slot for 5 minutes and if it's
not successful stops job.
I started investigation why bacula sometimes doesn't manage to load
slot in 5 minutes and find out library stops responding to commands
and starts cleaning drive procedure which takes more than 5
minutes(Library was configured to clean drive automatically)
So how can I solve the problem?
I've found place in mtx-changer script where declared 300 seconds to
wait. I've increased it value to 1800 seconds. Is it only place or I
have to change somthing else in sources?
Hi everybody.
Increasing timeout in mtx-changer script hasn't helped, I have the
same issue. Where in sources I can increase timeout to 30 minutes?
I don’t see why this is on devel It should be on users, which is cc’d
here.
------------------------------------------------------------------------------