>>>>> On Sat, 01 Feb 2020 00:15:07 +0200, Ian Douglas said:
> 
> hi all
> 
> Can someone who knows please advise if this is an issue with my database, my 
> tape server, the tape machine, or the tape?
> 
> The director machine (this machine) died (power failure) without being shut 
> down properly.
> 
> Tape server is HP, as is tape drive. Tape was out of drive, and I shut down 
> tape machine and tape server manually (via power buttons) before UPS expired.
> 
> I've tried a few times, including restarting MariaDB and the tape machine.
> 
> Google search showed other people with similar issue, but few years ago.
> 
> Thanks, Ian
> 
> 01-Feb 00:04 trooper-dir JobId 33471: shell command: run BeforeJob "/usr/
> libexec/bacula/make_catalog_backup.pl MyCatalog"
> 01-Feb 00:04 trooper-dir JobId 33471: Start Backup JobId 33471, 
> Job=BackupCatalog.2020-02-01_00.04.11_10
> 01-Feb 00:04 trooper-dir JobId 33471: Using Device "LTO-6" to write.
> 01-Feb 00:05 TapeServer JobId 33471: Volume "IncDiff-0012" previously 
> written, 
> moving to end of data.
> 01-Feb 00:06 TapeServer JobId 33471: Ready to append to end of Volume 
> "IncDiff-0012" at file=1237.
> 01-Feb 00:06 trooper-dir JobId 33471: Fatal error: catreq.c:426 Invalid 
> Catalog request: CatReq JobId=33471 UpdateMedia VolName=IncDiff-0012 
> VolJobs=327 VolFiles=1237 VolBlocks=14646107 VolBytes=944849719296 
> VolABytes=0 
> VolHoleBytes=0 VolHoles=0 VolMounts=131 VolErrors=0 VolWrites=256589848 
> MaxVolBytes=0 EndTime=1580508390 VolStatus=Append Slot=0 relabel=0 
> InChanger=0 
> VolReadTime=15412473 VolWriteTime=93282860606 VolFirstWritten=0 VolType=2 
> VolParts=0 VolCloudParts=0 LastPartBytes=0 Enabled=1

It looks like your Storage Daemon (TapeServer) is runnning an older Bacula
version than your Director (trooper-dir).  Bacula expects the versions to be
the same.