>>>>> On Sat, 01 Feb 2020 00:15:07 +0200, Ian Douglas said: > > hi all > > Can someone who knows please advise if this is an issue with my database, my > tape server, the tape machine, or the tape? > > The director machine (this machine) died (power failure) without being shut > down properly. > > Tape server is HP, as is tape drive. Tape was out of drive, and I shut down > tape machine and tape server manually (via power buttons) before UPS expired. > > I've tried a few times, including restarting MariaDB and the tape machine. > > Google search showed other people with similar issue, but few years ago. > > Thanks, Ian > > 01-Feb 00:04 trooper-dir JobId 33471: shell command: run BeforeJob "/usr/ > libexec/bacula/make_catalog_backup.pl MyCatalog" > 01-Feb 00:04 trooper-dir JobId 33471: Start Backup JobId 33471, > Job=BackupCatalog.2020-02-01_00.04.11_10 > 01-Feb 00:04 trooper-dir JobId 33471: Using Device "LTO-6" to write. > 01-Feb 00:05 TapeServer JobId 33471: Volume "IncDiff-0012" previously > written, > moving to end of data. > 01-Feb 00:06 TapeServer JobId 33471: Ready to append to end of Volume > "IncDiff-0012" at file=1237. > 01-Feb 00:06 trooper-dir JobId 33471: Fatal error: catreq.c:426 Invalid > Catalog request: CatReq JobId=33471 UpdateMedia VolName=IncDiff-0012 > VolJobs=327 VolFiles=1237 VolBlocks=14646107 VolBytes=944849719296 > VolABytes=0 > VolHoleBytes=0 VolHoles=0 VolMounts=131 VolErrors=0 VolWrites=256589848 > MaxVolBytes=0 EndTime=1580508390 VolStatus=Append Slot=0 relabel=0 > InChanger=0 > VolReadTime=15412473 VolWriteTime=93282860606 VolFirstWritten=0 VolType=2 > VolParts=0 VolCloudParts=0 LastPartBytes=0 Enabled=1
It looks like your Storage Daemon (TapeServer) is runnning an older Bacula version than your Director (trooper-dir). Bacula expects the versions to be the same. __Martin _______________________________________________ Bacula-users mailing list Bacula-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/bacula-users