Weird. It actually started reading from the tape when I did an unmount in bconsole (which is now blocked because the tape is in use)
Nico On Fri, May 29, 2020 at 1:46 PM Nico De Ranter <nico.deran...@esaturnus.com> wrote: > > Hi all, > > 2 months ago my postgres database got corrupted. As a result I am not able > to dump the database anymore. All other functionality still worked, only > the backup of the Bacula catalog failed every time. As I could not fix the > Postgresql issue I decided to reinstall the database from 2 months ago and > then use bscan to scan all tapes since. Unfortunately when I try to run > bscan it asks me to load a certain tape, however that tape is already > loaded and 'status slots' shows the right tape is available in the jukebox > and loaded in the drive. bscan just sits there and doesn't seem to be > doing anything. How can I convince bscan to start reading the tapes? > > Bacula version: 9.0.6 > OS version: Ubuntu 18.04.4 LTS > Tape device: Quantum Superload 3 with LTO-6 drive > > What I tried: > - dropped the old bacula database, recovered the latest usable database > from tape and installed it > - verified using bat that bacula is still running and I can see all data > (up to 2 months ago ofcourse) > - created a .bsr file containing a list of the volumes I want to scan > - bacula-dir, bacula-sd and bacula-fd are running on the server > > when I start bscan as follows: > > bscan -s -m -c /etc/bacula/bacula-sd.conf -v -b bscan-recover.bsr /dev/nst0 > > It says: > > bscan: butil.c:292-0 Using device: "/dev/nst0" for reading. > 29-May 13:43 bscan JobId 0: No slot defined in catalog (slot=0) for Volume > "MG3119L6" on "Superloader-Drive" (/dev/nst0). > 29-May 13:43 bscan JobId 0: Cartridge change or "update slots" may be > required. > > According to the console the tape is available and mounted > > *status slots > Automatically selected Storage: Jukebox > Connecting to Storage daemon Jukebox at backup.office:9103 ... > 3306 Issuing autochanger "slots" command. > Device "Superloader" has 8 slots. > Connecting to Storage daemon Jukebox at backup.office:9103 ... > 3306 Issuing autochanger "list" command. > > +------+----------------------+-----------+-----------------+--------------------+ > | Slot | Volume Name | Status | Media Type | Pool > | > > +------+----------------------+-----------+-----------------+--------------------+ > > +------+----------------------+-----------+-----------------+--------------------+ > | 1 | MG3119L6 | Append | LTO-6 | lto > | > > +------+----------------------+-----------+-----------------+--------------------+ > | 2 | OR7132L6 | Purged | LTO-6 | lto > | > > +------+----------------------+-----------+-----------------+--------------------+ > | 3 | NEH420L6 | Purged | LTO-6 | lto > | > > +------+----------------------+-----------+-----------------+--------------------+ > | 4 | NEH426L6 | Purged | LTO-6 | lto > | > > +------+----------------------+-----------+-----------------+--------------------+ > | 5 | NEH427L6 | Purged | LTO-6 | lto > | > > +------+----------------------+-----------+-----------------+--------------------+ > | 6 | NEH425L6 | Full | LTO-6 | lto > | > > +------+----------------------+-----------+-----------------+--------------------+ > | 7 | JI2317L6 | Full | LTO-6 | lto > | > > +------+----------------------+-----------+-----------------+--------------------+ > | 8 | CLN251L1 | Cleaning | | lto > | > *mount storage=Jukebox slot=1 drive=0 > 3001 Device ""Superloader-Drive" (/dev/nst0)" is mounted with Volume > "MG3119L6" > > What am I missing? > > Nico > > -- > > Nico De Ranter > > Operations Engineer > > T. +32 16 38 72 10 > > > <http://www.esaturnus.com> > [image: image.jpeg] > > > > > <http://www.esaturnus.com> > > > eSATURNUS > Philipssite 5, D, box 28 > 3001 Leuven – Belgium > > T. +32 16 40 12 82 > F. +32 16 40 84 77 > www.esaturnus.com > > <http://www.esaturnus.com/> > > *For Service & Support :* > > Support Line Belgium: +32 2 2009897 > > Support Line International: +44 12 56 68 38 78 > > Or via email : medical.services...@sony.com > > > -- Nico De Ranter Operations Engineer T. +32 16 38 72 10 <http://www.esaturnus.com> <http://www.esaturnus.com> eSATURNUS Philipssite 5, D, box 28 3001 Leuven – Belgium T. +32 16 40 12 82 F. +32 16 40 84 77 www.esaturnus.com <http://www.esaturnus.com/> *For Service & Support :* Support Line Belgium: +32 2 2009897 Support Line International: +44 12 56 68 38 78 Or via email : medical.services...@sony.com
_______________________________________________ Bacula-users mailing list Bacula-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/bacula-users