Weird. It actually started reading from the tape when I did an unmount in
bconsole (which is now blocked because the tape is in use)

Nico

On Fri, May 29, 2020 at 1:46 PM Nico De Ranter <nico.deran...@esaturnus.com>
wrote:

>
> Hi all,
>
> 2 months ago my postgres database got corrupted. As a result I am not able
> to dump the database anymore.  All other functionality still worked, only
> the backup of the Bacula catalog failed every time.  As I could not fix the
> Postgresql issue I decided to reinstall the database from 2 months ago and
> then use bscan to scan all tapes since.  Unfortunately when I try to run
> bscan it asks me to load a certain tape, however that tape is already
> loaded and 'status slots' shows the right tape is available in the jukebox
> and loaded in the drive.  bscan just sits there and doesn't seem to be
> doing anything.   How can I convince bscan to start reading the tapes?
>
> Bacula version:  9.0.6
> OS version: Ubuntu 18.04.4 LTS
> Tape device: Quantum Superload 3 with LTO-6 drive
>
> What I tried:
> - dropped the old bacula database, recovered the latest usable database
> from tape and installed it
> - verified using bat that bacula is still running and I can see all data
> (up to 2 months ago ofcourse)
> - created a .bsr file containing a list of the volumes I want to scan
> - bacula-dir, bacula-sd and bacula-fd are running on the server
>
> when I start bscan as follows:
>
> bscan -s -m -c /etc/bacula/bacula-sd.conf -v -b bscan-recover.bsr /dev/nst0
>
> It says:
>
> bscan: butil.c:292-0 Using device: "/dev/nst0" for reading.
> 29-May 13:43 bscan JobId 0: No slot defined in catalog (slot=0) for Volume
> "MG3119L6" on "Superloader-Drive" (/dev/nst0).
> 29-May 13:43 bscan JobId 0: Cartridge change or "update slots" may be
> required.
>
> According to the console the tape is available and mounted
>
> *status slots
> Automatically selected Storage: Jukebox
> Connecting to Storage daemon Jukebox at backup.office:9103 ...
> 3306 Issuing autochanger "slots" command.
> Device "Superloader" has 8 slots.
> Connecting to Storage daemon Jukebox at backup.office:9103 ...
> 3306 Issuing autochanger "list" command.
>
> +------+----------------------+-----------+-----------------+--------------------+
> | Slot | Volume Name          | Status    | Media Type      | Pool
>       |
>
> +------+----------------------+-----------+-----------------+--------------------+
>
> +------+----------------------+-----------+-----------------+--------------------+
> |    1 | MG3119L6             | Append    | LTO-6           | lto
>        |
>
> +------+----------------------+-----------+-----------------+--------------------+
> |    2 | OR7132L6             | Purged    | LTO-6           | lto
>        |
>
> +------+----------------------+-----------+-----------------+--------------------+
> |    3 | NEH420L6             | Purged    | LTO-6           | lto
>        |
>
> +------+----------------------+-----------+-----------------+--------------------+
> |    4 | NEH426L6             | Purged    | LTO-6           | lto
>        |
>
> +------+----------------------+-----------+-----------------+--------------------+
> |    5 | NEH427L6             | Purged    | LTO-6           | lto
>        |
>
> +------+----------------------+-----------+-----------------+--------------------+
> |    6 | NEH425L6             | Full      | LTO-6           | lto
>        |
>
> +------+----------------------+-----------+-----------------+--------------------+
> |    7 | JI2317L6             | Full      | LTO-6           | lto
>        |
>
> +------+----------------------+-----------+-----------------+--------------------+
> |    8 | CLN251L1             | Cleaning  |                 | lto
>        |
> *mount storage=Jukebox slot=1 drive=0
> 3001 Device ""Superloader-Drive" (/dev/nst0)" is mounted with Volume
> "MG3119L6"
>
> What am I missing?
>
> Nico
>
> --
>
> Nico De Ranter
>
> Operations Engineer
>
> T. +32 16 38 72 10
>
>
> <http://www.esaturnus.com>
> [image: image.jpeg]
>
>
>
>
> <http://www.esaturnus.com>
>
>
> eSATURNUS
> Philipssite 5, D, box 28
> 3001 Leuven – Belgium
>
> T. +32 16 40 12 82
> F. +32 16 40 84 77
> www.esaturnus.com
>
> <http://www.esaturnus.com/>
>
> *For Service & Support :*
>
> Support Line Belgium: +32 2 2009897
>
> Support Line International: +44 12 56 68 38 78
>
> Or via email : medical.services...@sony.com
>
>
>

-- 

Nico De Ranter

Operations Engineer

T. +32 16 38 72 10


<http://www.esaturnus.com>

<http://www.esaturnus.com>


eSATURNUS
Philipssite 5, D, box 28
3001 Leuven – Belgium

T. +32 16 40 12 82
F. +32 16 40 84 77
www.esaturnus.com

<http://www.esaturnus.com/>

*For Service & Support :*

Support Line Belgium: +32 2 2009897

Support Line International: +44 12 56 68 38 78

Or via email : medical.services...@sony.com
_______________________________________________
Bacula-users mailing list
Bacula-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/bacula-users