Hello, śr., 10 lis 2021 o 12:08 Jeffrey Di Domenico <jdidomen...@integrafin.co.uk> napisał(a):
> Hi, > > Thanks for responding. > > I assume you are trying to use a standard SCSI library and not the ACSLS > managed one, right? - yes. > > The rest of the answers are below, the mtx -f command fails so that > doesn't seem to be working, I hadn't tried that yet so have only just seen > it, also mtx-changer command doesn't exist. > The `mtx-changer` command is located at Bacula's script directory, so in my setup it is at: `/opt/bacula/scripts/mtx-changer`. It is not at the $PATH until you explicitly add it. > > [root@union dev]# mtx -f /dev/sg38 status > mtx: Request Sense: Long Report=yes > mtx: Request Sense: Valid Residual=no > mtx: Request Sense: Error Code=70 (Current) > mtx: Request Sense: Sense Key=Illegal Request > mtx: Request Sense: FileMark=no > mtx: Request Sense: EOM=no > mtx: Request Sense: ILI=no > mtx: Request Sense: Additional Sense Code = 20 > mtx: Request Sense: Additional Sense Qualifier = 00 > mtx: Request Sense: BPV=no > mtx: Request Sense: Error in CDB=no > mtx: Request Sense: SKSV=no > READ ELEMENT STATUS Command Failed > [root@union dev]# mtx -f /dev/sg40 status > mtx: Request Sense: Long Report=yes > mtx: Request Sense: Valid Residual=no > mtx: Request Sense: Error Code=70 (Current) > mtx: Request Sense: Sense Key=Illegal Request > mtx: Request Sense: FileMark=no > mtx: Request Sense: EOM=no > mtx: Request Sense: ILI=no > mtx: Request Sense: Additional Sense Code = 20 > mtx: Request Sense: Additional Sense Qualifier = 00 > mtx: Request Sense: BPV=no > mtx: Request Sense: Error in CDB=no > mtx: Request Sense: SKSV=no > READ ELEMENT STATUS Command Failed > [root@union dev]# > You should resolve the errors above before you will be able to use Bacula for this library. BTW. Are you sure that `/dev/sg38` and `/dev/sg40` are your changer devices? What does `lsscsi -g | grep mediumx` show? > > > [root@union dev]# mtx -f /dev/sg40 inquiry > Product Type: Tape Drive > Vendor ID: 'HP ' > Product ID: 'Ultrium 5-SCSI ' > Revision: 'Y6PW' > Attached Changer API: No > [root@union dev]# mtx -f /dev/sg38 inquiry > Product Type: Tape Drive > Vendor ID: 'HP ' > Product ID: 'Ultrium 5-SCSI ' > Revision: 'Y6PW' > Attached Changer API: No > So `/dev/sg40` is not your changer device for sure. It is a tape drive device. > [root@union dev]# > > [root@union dev]# mtx-changer /dev/sg40 listall > -bash: mtx-changer: command not found > Check where your mtx-changer script from Bacula distribution is located. I hope this helps. -- Radosław Korzeniewski rados...@korzeniewski.net
_______________________________________________ Bacula-users mailing list Bacula-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/bacula-users