Hello.

> On 13:26 Mon 11 Mar     , Alexander Shiyan wrote:
> > This patch adds support for COMMON_CLK API for CLPS711X targets.
> > 
> > Signed-off-by: Alexander Shiyan <[email protected]>
...
> > +   /* Turn timers in free running mode */
> >     tmp = readl(SYSCON1);
> > -   tmp &= ~SYSCON1_TC2M;   /* Free running mode */
> > -   tmp |= SYSCON1_TC2S;    /* High frequency source */
> > +   tmp &= ~(SYSCON1_TC1M | SYSCON1_TC2M);
> >     writel(tmp, SYSCON1);
> this is timer configuration not clocks

We need to read counter value for clocksource, so we need to ensure
that we have full range of values (0x0 - 0xffff). It mean that timer/counters
should not be in prescaler mode. All correct.
Thanks.

---