On Thu, Jun 28, 2018 at 06:29:05PM +0200, Philipp Zabel wrote:
> On i.MX6QP/DP cpu_mx6_is_mx6q/d do not return true anymore.
> Use the new cpu_mx6_is_mx6qp/dp to reenable NoC regulator bypass.
>
> Fixes: d4c05d29d484 ("ARM: i.MX6: Add cpu type for 'plus' variants")
> Signed-off-by: Philipp Zabel <[email protected]>
> ---
> arch/arm/mach-imx/imx6.c | 3 +--
> 1 file changed, 1 insertion(+), 2 deletions(-)
>
Applied, thanks
Sascha
> diff --git a/arch/arm/mach-imx/imx6.c b/arch/arm/mach-imx/imx6.c
> index eaf9f2e4130e..3d95c9e3749c 100644
> --- a/arch/arm/mach-imx/imx6.c
> +++ b/arch/arm/mach-imx/imx6.c
> @@ -140,8 +140,7 @@ static void imx6_setup_ipu_qos(void)
> * On i.MX6 QP/DP the NoC regulator for the IPU ports needs to be in
> * bypass mode for the above settings to take effect.
> */
> - if ((cpu_mx6_is_mx6q() || cpu_mx6_is_mx6d()) &&
> - imx_silicon_revision() >= IMX_CHIP_REV_2_0) {
> + if (cpu_mx6_is_mx6qp() || cpu_mx6_is_mx6dp()) {
> writel(0x2, fast2 + 0xb048c);
> writel(0x2, fast2 + 0xb050c);
> }
> --
> 2.17.1
>
>
> _______________________________________________
> barebox mailing list
> [email protected]
> http://lists.infradead.org/mailman/listinfo/barebox
>
--
Pengutronix e.K. | |
Industrial Linux Solutions | http://www.pengutronix.de/ |
Peiner Str. 6-8, 31137 Hildesheim, Germany | Phone: +49-5121-206917-0 |
Amtsgericht Hildesheim, HRA 2686 | Fax: +49-5121-206917-5555 |
_______________________________________________
barebox mailing list
[email protected]
http://lists.infradead.org/mailman/listinfo/barebox