A status = "disabled" node should act the same as if it were
uncommented, with the difference that a board that does have the
resistor populated could easily fixup the status.

Signed-off-by: Ahmad Fatoum <[email protected]>
---
 arch/arm/dts/imx7d-pba-c-09.dtsi | 3 +--
 1 file changed, 1 insertion(+), 2 deletions(-)

diff --git a/arch/arm/dts/imx7d-pba-c-09.dtsi b/arch/arm/dts/imx7d-pba-c-09.dtsi
index 7106d6bfd735..0b2a987fd440 100644
--- a/arch/arm/dts/imx7d-pba-c-09.dtsi
+++ b/arch/arm/dts/imx7d-pba-c-09.dtsi
@@ -36,7 +36,6 @@
                };
 
                /* Enable if R9 is populated. Conflicts with userbtn2 on 
PEB-EVAL-02 */
-               /*
                reg_can1_3v3: regulator@2 {
                        compatible = "regulator-fixed";
                        reg = <2>;
@@ -45,8 +44,8 @@
                        regulator-max-microvolt = <3300000>;
                        gpio = <&gpio5 2 GPIO_ACTIVE_HIGH>;
                        enable-active-high;
+                       status = "disabled";
                };
-               */
        };
 };
 
-- 
2.27.0


_______________________________________________
barebox mailing list
[email protected]
http://lists.infradead.org/mailman/listinfo/barebox