On Mon, Jun 22, 2020 at 11:53:51AM +0200, Ahmad Fatoum wrote:
> Upstream of_clk_get_parent_name only resorts to node name as a fallback.
> Instead, it uses the name supplied for registered clocks whenever
> possible. On the sama5d2, this results in sckc@f8048050 and slowck,
> respectively. So far, sckc@f8048050 in the parents array couldn't be
> matched with any existing clock, leading to an inaccurate clock tree.
> 
> Port over the v5.8-rc1 state of the function to fix this.
> 
> Signed-off-by: Ahmad Fatoum <a.fat...@pengutronix.de>
> ---
>  drivers/clk/clk.c   | 49 ++++++++++++++++++++++++++++++++++++++++-----
>  include/linux/clk.h |  2 +-
>  2 files changed, 45 insertions(+), 6 deletions(-)

Applied, thanks

Sascha

> 
> diff --git a/drivers/clk/clk.c b/drivers/clk/clk.c
> index 4386c95aa9ec..f2e459a76018 100644
> --- a/drivers/clk/clk.c
> +++ b/drivers/clk/clk.c
> @@ -469,21 +469,60 @@ unsigned int of_clk_get_parent_count(struct device_node 
> *np)
>  }
>  EXPORT_SYMBOL_GPL(of_clk_get_parent_count);
>  
> -char *of_clk_get_parent_name(struct device_node *np, unsigned int index)
> +char *of_clk_get_parent_name(const struct device_node *np, int index)
>  {
>       struct of_phandle_args clkspec;
> +     struct property *prop;
>       const char *clk_name;
> +     const __be32 *vp;
> +     u32 pv;
>       int rc;
> +     int count;
> +     struct clk *clk;
>  
>       rc = of_parse_phandle_with_args(np, "clocks", "#clock-cells", index,
> -                     &clkspec);
> +                                     &clkspec);
>       if (rc)
>               return NULL;
>  
> +     index = clkspec.args_count ? clkspec.args[0] : 0;
> +     count = 0;
> +
> +     /* if there is an indices property, use it to transfer the index
> +      * specified into an array offset for the clock-output-names property.
> +      */
> +     of_property_for_each_u32(clkspec.np, "clock-indices", prop, vp, pv) {
> +             if (index == pv) {
> +                     index = count;
> +                     break;
> +             }
> +             count++;
> +     }
> +     /* We went off the end of 'clock-indices' without finding it */
> +     if (prop && !vp)
> +             return NULL;
> +
>       if (of_property_read_string_index(clkspec.np, "clock-output-names",
> -                             clkspec.args_count ? clkspec.args[0] : 0,
> -                             &clk_name) < 0)
> -             clk_name = clkspec.np->name;
> +                                       index,
> +                                       &clk_name) < 0) {
> +             /*
> +              * Best effort to get the name if the clock has been
> +              * registered with the framework. If the clock isn't
> +              * registered, we return the node name as the name of
> +              * the clock as long as #clock-cells = 0.
> +              */
> +             clk = of_clk_get_from_provider(&clkspec);
> +             if (IS_ERR(clk)) {
> +                     if (clkspec.args_count == 0)
> +                             clk_name = clkspec.np->name;
> +                     else
> +                             clk_name = NULL;
> +             } else {
> +                     clk_name = __clk_get_name(clk);
> +                     clk_put(clk);
> +             }
> +     }
> +
>  
>       return xstrdup(clk_name);
>  }
> diff --git a/include/linux/clk.h b/include/linux/clk.h
> index a005e7233de8..d14d8b96a342 100644
> --- a/include/linux/clk.h
> +++ b/include/linux/clk.h
> @@ -556,7 +556,7 @@ struct string_list;
>  
>  int clk_name_complete(struct string_list *sl, char *instr);
>  
> -char *of_clk_get_parent_name(struct device_node *np, unsigned int index);
> +char *of_clk_get_parent_name(const struct device_node *np, int index);
>  
>  static inline void clk_unregister(struct clk *clk)
>  {
> -- 
> 2.27.0
> 
> 
> _______________________________________________
> barebox mailing list
> barebox@lists.infradead.org
> http://lists.infradead.org/mailman/listinfo/barebox
> 

-- 
Pengutronix e.K.                           |                             |
Steuerwalder Str. 21                       | http://www.pengutronix.de/  |
31137 Hildesheim, Germany                  | Phone: +49-5121-206917-0    |
Amtsgericht Hildesheim, HRA 2686           | Fax:   +49-5121-206917-5555 |

_______________________________________________
barebox mailing list
barebox@lists.infradead.org
http://lists.infradead.org/mailman/listinfo/barebox

Reply via email to