On Fri, Sep 30, 2022 at 01:19:40PM +0200, Ahmad Fatoum wrote:
> We don't usually disable MMC controllers on barebox shutdown, because
> they don't DMA on their own, unlike e.g. network controllers.
> 
> Booting Linux v5.17.0 on a Raspberry Pi 4 in 32-bit mode still has the
> MMC host controller driver complain:
> 
>   [   22.464887] mmc1: Got data interrupt 0x00000002 even though no
>                       data operation was in progress.
> 
> Fix this by resetting the SDHCI once barebox is done with it.
> 
> Signed-off-by: Ahmad Fatoum <[email protected]>
> ---
>  drivers/mci/mci-bcm2835.c | 12 ++++++++++++
>  1 file changed, 12 insertions(+)

Applied, thanks

Sascha

> 
> diff --git a/drivers/mci/mci-bcm2835.c b/drivers/mci/mci-bcm2835.c
> index f092156f9a83..c5b226ba033c 100644
> --- a/drivers/mci/mci-bcm2835.c
> +++ b/drivers/mci/mci-bcm2835.c
> @@ -385,6 +385,8 @@ static int bcm2835_mci_probe(struct device_d *hw_dev)
>       host->sdhci.read32 = bcm2835_sdhci_read32;
>       host->sdhci.write32 = bcm2835_sdhci_write32;
>  
> +     hw_dev->priv = host;
> +
>       mci_of_parse(&host->mci);
>  
>       iores = dev_request_mem_resource(hw_dev, 0);
> @@ -420,6 +422,15 @@ static int bcm2835_mci_probe(struct device_d *hw_dev)
>       return mci_register(&host->mci);
>  }
>  
> +static void bcm2835_mci_remove(struct device_d *dev)
> +{
> +     struct bcm2835_mci_host *host = dev->priv;
> +
> +     sdhci_write32(&host->sdhci,
> +                   SDHCI_CLOCK_CONTROL__TIMEOUT_CONTROL__SOFTWARE_RESET,
> +                   0x00);
> +}
> +
>  static __maybe_unused struct of_device_id bcm2835_mci_compatible[] = {
>       {
>               .compatible = "brcm,bcm2835-sdhci",
> @@ -433,6 +444,7 @@ static __maybe_unused struct of_device_id 
> bcm2835_mci_compatible[] = {
>  static struct driver_d bcm2835_mci_driver = {
>       .name = "bcm2835_mci",
>       .probe = bcm2835_mci_probe,
> +     .remove = bcm2835_mci_remove,
>       .of_compatible = DRV_OF_COMPAT(bcm2835_mci_compatible),
>  };
>  
> -- 
> 2.30.2
> 
> 
> 

-- 
Pengutronix e.K.                           |                             |
Steuerwalder Str. 21                       | http://www.pengutronix.de/  |
31137 Hildesheim, Germany                  | Phone: +49-5121-206917-0    |
Amtsgericht Hildesheim, HRA 2686           | Fax:   +49-5121-206917-5555 |