On Wed, Nov 30, 2022 at 06:14:39PM +0100, Ahmad Fatoum wrote:
> Driver was written to mimic existing stpmic1 regulator driver, which had
> the implicit assumption of a 1:1 relationship between of_match_data and
> regulator configuration with same indices.
>
> Yet DCDC_REG5 was not at the same place it was in the rk_regulator_cfg
> due to likely a copy-paste mistake, leading to possibly the wrong
> regulators being controlled. Fix this.
>
> Reported-by: Michael Riesch <[email protected]>
> Suggested-by: Michael Riesch <[email protected]>
> Signed-off-by: Ahmad Fatoum <[email protected]>
> ---
> move entry in rk809_reg, not rk809_reg_matches to keep same numbering as
> enum rk809_reg_id.
> ---
> drivers/regulator/rk808-regulator.c | 27 ++++++++++++++-------------
> 1 file changed, 14 insertions(+), 13 deletions(-)
Applied, thanks
Sascha
>
> diff --git a/drivers/regulator/rk808-regulator.c
> b/drivers/regulator/rk808-regulator.c
> index 39eadbd3ebe5..f8bc31f354e2 100644
> --- a/ drivers/regulator/rk808-regulator.c
> +++ b/drivers/regulator/rk808-regulator.c
> @@ -526,19 +526,6 @@ static struct rk_regulator_cfg rk809_reg[] = {
> .enable_mask = ENABLE_MASK(RK817_ID_DCDC4),
> .enable_val = ENABLE_MASK(RK817_ID_DCDC4),
> .disable_val = DISABLE_VAL(RK817_ID_DCDC4),
> - }}, {{
> - /* .name = "DCDC_REG5", */
> - .supply_name = "vcc9",
> - .ops = &rk809_buck5_ops_range,
> - .n_voltages = RK809_BUCK5_SEL_CNT,
> - .linear_ranges = rk809_buck5_voltage_ranges,
> - .n_linear_ranges = ARRAY_SIZE(rk809_buck5_voltage_ranges),
> - .vsel_reg = RK809_BUCK5_CONFIG(0),
> - .vsel_mask = RK809_BUCK5_VSEL_MASK,
> - .enable_reg = RK817_POWER_EN_REG(3),
> - .enable_mask = ENABLE_MASK(1),
> - .enable_val = ENABLE_MASK(1),
> - .disable_val = DISABLE_VAL(1),
> }},
> RK817_DESC(/* "LDO_REG1", */ "vcc5", 600, 3400, 25,
> RK817_LDO_ON_VSEL_REG(0), RK817_LDO_VSEL_MASK,
> @@ -576,6 +563,20 @@ static struct rk_regulator_cfg rk809_reg[] = {
> RK817_LDO_ON_VSEL_REG(8), RK817_LDO_VSEL_MASK,
> RK817_POWER_EN_REG(3), ENABLE_MASK(0),
> DISABLE_VAL(0), 400),
> + {{
> + /* .name = "DCDC_REG5", */
> + .supply_name = "vcc9",
> + .ops = &rk809_buck5_ops_range,
> + .n_voltages = RK809_BUCK5_SEL_CNT,
> + .linear_ranges = rk809_buck5_voltage_ranges,
> + .n_linear_ranges = ARRAY_SIZE(rk809_buck5_voltage_ranges),
> + .vsel_reg = RK809_BUCK5_CONFIG(0),
> + .vsel_mask = RK809_BUCK5_VSEL_MASK,
> + .enable_reg = RK817_POWER_EN_REG(3),
> + .enable_mask = ENABLE_MASK(1),
> + .enable_val = ENABLE_MASK(1),
> + .disable_val = DISABLE_VAL(1),
> + }},
> RK817_DESC_SWITCH(/* "SWITCH_REG1", */ "vcc9",
> RK817_POWER_EN_REG(3), ENABLE_MASK(2),
> DISABLE_VAL(2)),
> RK817_DESC_SWITCH(/* "SWITCH_REG2", */ "vcc8",
> --
> 2.30.2
>
>
>
--
Pengutronix e.K. | |
Steuerwalder Str. 21 | http://www.pengutronix.de/ |
31137 Hildesheim, Germany | Phone: +49-5121-206917-0 |
Amtsgericht Hildesheim, HRA 2686 | Fax: +49-5121-206917-5555 |