On 23-09-20, Sascha Hauer wrote:
> When voltage constraints are given in the device tree then we should
> set the regulator to a valid voltage before enabling it. Without it
> we can end up with invalid voltages.
> 
> Signed-off-by: Sascha Hauer <[email protected]>

Reviewed-by: Marco Felsch <[email protected]>