Not sure if the "coupler" you are talking about is a union .  If it is a union, 
it will have to hex  ends on it so you can get wrenches on it to take it apart. 
 If so, remove and replace it and the piece of pipe that goes to the ninety at 
the meter.  If it is a coupler, sometimes called a collar, remove it and then 
replace it with a union and piece of pipe as I mentioned above.
  ----- Original Message ----- 
  From: Shane Hecker 
  To: [email protected] 
  Sent: Wednesday, April 30, 2008 23:11
  Subject: [BlindHandyMan] gas hell yes I got gas


  In the back yard that is. Lets put it this way. When a totally blind person 
  can see the gas leak, it's time to fix it. This one is about a half inch to 
  an inch above the ground (on my side of course). Have no idea how long it's 
  been leaking like that. Anyway, it was the gas technician from the city who 
  came out and helped me find it. So here's what I want to do for the repair, 
  but first some other information.
  I don't know who ran this line, but here's what they did. They have the 
  standard 90 coming off the meter. The pipe goes down into the ground which 
  is standard. But where the leak is and where the pipe broke off (after the 
  gas technician tried getting it out) there is a coupling. That coupling is 
  what came apart. Then, there is the piece on the other side which goes into 
  the ground. My question is why wasn't a piece of pipe run all the way down? 
  Why put the coupling there? For now, the technician put a rag on top of the 
  pipe to keep moisture out of it. I should say stuffed then laid the rest on 
  top. I plan to take that coupling and the remaining piece of pipe off. Ain't 
  digging fun? Then, it's time for a trip to home depot for a measurement. 
  Or, I could just cut the pipe (black pipe that is) myself. I've got the 
  cutter to do it with along with a talking tape measure so it shouldn't be 
  too bad. Threading isn't a problem either. The pipe is 1 inch. Then I plan 
  to coat the pipe threads with plenty of the pipe dope. Then comes 
  reassembly. Finally, a call to the city will be in order for them to come 
  inspect it and hopefully turn the gas back on. One other thing, the gas 
  technician tells me that if I'm replacing 5 feet or less I don't need a 
  permit to do it, so lets hope it's less than 5 feet.
  Now for some questions. Is there anything I should be aware of when digging 
  along the pipe? Is there anything else I might have missed? Any input is 
  appreciated. Oh, and in case someone asks "why don't you have a licensed 
  plumber do it?", my answer is I don't want to pay a rediculous price for 
  them to do it when I could do it myself for a fraction of that price.

  Shane 



   

[Non-text portions of this message have been removed]

Reply via email to