Shane, that union is there for a reason.  Gas lines do need a pressure 
check.  Normal operating pressure is one half psi or one quarter psi 
approximately depending on gas, in your case probably one quarter.  That is the 
pressure the meter has to regulate out into that line.  There is no way to 
pressure check the line for leaks with out it facing the meter unit and 
possibly damaging it to cause bad regulation afterwards.  One can not install a 
gas cock to shut it off from the meter either because they leak under pressure 
checks making a pressure check impossible.  So now the problem is how to 
connect a checked gas line to a meter when neither can be turned, solution is a 
union that ties the two together.  A union allows future repair without cutting 
the line or running all new.  That is before the new plastic gas lines with all 
compression fittings.