This is exactly how I wired up my quartz infrared heater.  I like to have the 
breaker in my hand when attaching the hot red / black
wires.  I then snap it onto the bus.  Most people, who can see, just work on 
the breaker when it is  snapped in.  I use a color
identifier when I'm messing with wire.

Now, I know my box.  I know where the mains come in and attach.  There is an 
area at the top of the box, if touched, would light up
your life even if the mains are off.  I can't imagine getting my hands in a 
unfamiliar box.  It makes me nervous enough in mine.

Terry
On Thu, 5 Feb 2009 20:07:10 -0600you write:
>
>Just an insert from aside.  I have very little usabble vision and if I am 
>installing a circuit you can do most of the stripping et
>c from outside the box once you have the cable in.  I attach theneutral and 
>ground wire.  Sometimes with light I can tell the diff
>erence between black and white.  And since these bars are grounded there isn't 
>a problem.  I then put the wire on the breaker I am
> using and then snap it into the hot buss bars and then turn it on.  If I am 
> feeling nervous I wear dry leather gloves also.
>Ron
>  ----- Original Message ----- 
>  From: Alan & Terrie Robbins 
>  To: [email protected] 
>  Sent: Thursday, February 05, 2009 7:01 PM
>  Subject: RE: [BlindHandyMan] Run-down on Louisiana work trip
>
>
>  Dale,
>
>  I used to do this stuff in boxes when I had some vision but have not done so
>  now that I have practically none. Question for you, when you are in the
>  main breaker box do you shut off the main breaker before poking around in
>  there?
>
>  thanks
>  Al

Reply via email to