The steam valve works just like a hose faucet, easy to repair.

The group lever should not be left in the center position -- thus, a
non-issue.

dave



On Aug 25, 9:11 am, Bruce Keeler <[email protected]> wrote:
> I've noticed two water leakage problems lately.
>
> First, my steam wand has been dripping steadily, even when the knob is
> turned all the way off.  It's enough that it's no longer "no-burn", but
> always hot.
>
> Second, the group leaks when the lever is in the middle position.  It's
> fine when it's all the way down, however.
>
> I guess some seals in there need replacing.  Is this a difficult job?
>
> Bruce

--~--~---------~--~----~------------~-------~--~----~
You received this message because you are subscribed to the Google Groups 
"Brewtus" group.
To post to this group, send email to [email protected]
To unsubscribe from this group, send email to 
[email protected]
For more options, visit this group at 
http://groups.google.com/group/brewtus?hl=en
-~----------~----~----~----~------~----~------~--~---

Reply via email to