I had a similar issue last year.  I started by cleaning inside the top of the 
"E61" head (removing the large chrome nut, and cleaning the stuff inside, 
etc.).  I then cleaned the OPV.  I eventually replaced it (OPV) even though it 
was spotless.  Neither of these helped. In my case, it came down to diassembly 
of the vibe pump and cleaning.  I know this is not recommended, but it looked 
like a very simple mechanism to me.  What I discovered was bits of thread 
sealant had come off and were plugging up the small openings at the outlet end 
(if my memory is correct).  Since then, no problems.  Along with the OPV I 
ordered a Vibe pump, which eventually came, but I have not replaced it yet.  
    

                                          