I've had my refurbed Brewtus II for more than a year, but this is my
first post. (I've actively lurked, but this is the first time I've
needed help...)

Over the past month, my brew pressure during shots has gradually and
sporadically failed, which is to say, gone from 8.5-9 bars down to 3-4
bars. Quality of espresso has gone down accordingly from thick with
rich crema to watery coffee.

When this pressure problem first happened, I could flip the pump
actuator lever off and immediately back on, and pressure would ramp
back up to normal. Now it stays at 3-4 bars no matter what I do.

My hunch is that this isn't a pump failure, since the sound the pump
makes hasn't changed at all, and backflushing with a blind basket
still produces a steady 10.5 bars of pressure, just as it always did.

So, Brewtus experts, what's gone wrong? OPV valve? Seals? And can I
repair this myself, or is it safer to drive my Brewtus 50 miles from
where I live on the Oregon coast over the coastal mountains to
Stefano's Espresso Care?

--Bill

-- 