You will need more that a nats whisker of a turn... I would go in a two turns... Test.
Go out to the start position and then another 2 turns out ... Test Then go back to the start. Test Could be a bit of crap / scale that is causing sticking... After that a Clean and de scale and after that replace. Have found that most problems is due to scale and or crap causing things to stick... On May 10, 7:47 am, Chris Bailey <[email protected]> wrote: > I've seen others complain of similar problems, and so I believe I probably > need an new OPV value, but before I order that... > > I've had my Brewtus II about 3 years. Recently, I found that not too long > into extraction, the pressure just drops, fairly quickly. And I mean it > drops say to 4 bar - this is not a grind problem or what not. Sometimes > it'll ramp back up, but most of the time not. > > I've tried slightly (turned from maybe 12 o'clock to 1 o'clock position) > tightening/increasing the pressure (with the screw behind the drip tray), > but to no avail. Anything else I can try? I have no problem replacing > parts, etc. if that's the best way to go. If so, should i order it from > Whole Latte Love, or? Anything else folks suggest once I open up the > machine? > > -- > Chris Bailey > [email protected] > @chrisrbailey -- You received this message because you are subscribed to the Google Groups "Brewtus" group. To post to this group, send email to [email protected]. To unsubscribe from this group, send email to [email protected]. For more options, visit this group at http://groups.google.com/group/brewtus?hl=en.