The sensor is located in the thermowell and the thermal compound probably has hardened.
Wait for Ira's response but you should probably just tape with heat resistant electrical tape. On May 19, 9:36 am, Fred <[email protected]> wrote: > Hi Ira, > > Thank you for your quick response. I checked the black wire and > actually it's cracked right in the border on the top of the boiler. > How can I fixed that? Should I just pull the wire and tape it? I tried > to pull the wire and feel some resistant. If I pull it out how can I > reattached? > > Thanks, > > On May 19, 2:33 am, Ira <[email protected]> wrote: > > > > > At 06:29 PM 5/18/2011, you wrote: > > > >Could be the temperature sensor in the boiler, a cheap but difficult > > >part to locate. > > > Check the skinnyblack wirethat runs from the back of the controller > > to the well in the brew boiler. The wire can crack in the heat and > > intermittently short out causing the kind of problem you're seeing. > > > Ira -- You received this message because you are subscribed to the Google Groups "Brewtus" group. To post to this group, send email to [email protected]. To unsubscribe from this group, send email to [email protected]. For more options, visit this group at http://groups.google.com/group/brewtus?hl=en.