hello james,

the thing with pre-infusion is, that there's little pressure. coffee extracted without pressure but with hot water (say, drip coffee) takes several minutes. it's the pressure that sets espresso apart, and makes the extraction time so short compared to other methods.

so in this respect, your idea of not counting pre-infusion makes sense.

but, i think a pre-infusion time of 6-8 seconds is nothing out of the ordinary. with a manual lever machines, this is what you aim for as a starting point, say somewhere between 4 and 8 seconds. with other machine i've worked with, inclusing the industrial pavoni's they have at one place where i work, espresso often takes about 5 seconds to start flowing. even if you added a second or two for your brewtus, you will still likely to end up in the 25-30 seconds range.

and here's where i am not sure, but i suppose that (a normal) pre-infusion time was accounted for when setting these 'standards'. as far as i know, most barista's do count the pre-infusion time. the clock starts when they switch the machine's lever or hit the button.

i have thought about this subject with my brewtus iv vibrational pump machine, which extends the pre-infusion time beyond any other brewtus machines, it actually doubles this time more or less. i might or might not have to add about 5 or 6 seconds extra to my timing to extract the same amount of coffee without increasing the flow rate compared to other machines with a more normal pre-infusion time. but this is no issue for the other brewtus machines.

have a great weekend,
guido.

Hello everyone, and apologies if this has been discussed before. I've
been wondering about the magic mid-20's number for shot timings, when
different machines operate in a different manner. This is noticeable
when you consider the instant pour of many machines with the almost
zero pressure of the Brewtus for the first 6 or so seconds. Do these
seconds count, or do E61 users ignore the preinfusion timing?

--
You received this message because you are subscribed to the Google Groups 
"Brewtus" group.
To post to this group, send email to [email protected].
To unsubscribe from this group, send email to 
[email protected].
For more options, visit this group at 
http://groups.google.com/group/brewtus?hl=en.

Reply via email to