Hello winnipegger65,

Friday, July 5, 2013, 9:25:32 AM, you wrote:


Here's something which makes no sense to me. Once, I was not pulling a shot at 
all but steaming milk. I was steaming for maybe 30 seconds or so and noticed 
the PID temperature dropped from 96 to 95 degrees. That's not even coming from 
the same boiler so why the brew temperature would fall is a mystery to me.

Any thoughts?


Bad ground, loose wire, dying RTD or PID. The symptoms don't seem to make sense 
knowing what I know about how a Brewtus works. Do you have any way to check if 
the boiler temperature is actually dropping?

-- Ira

-- 