Hey Todd, Switched the wires as you suggested and kept a close eye on the temperatures. I measured the external temperature of the boiler as time went on and ended up with these numbers.
Starting temp: 70F After 2 min: 110F After 3 min: 128F After 4 min: 144F (Times are after turning the machine on, not from the last data point) Please let me know your thoughts. Thanks, Jorge On Thursday, November 19, 2015 at 6:33:16 PM UTC-5, Jorge See wrote: > > Hello, > I have a BII that is unmodified and received a tune up a few years ago at > WLL. The brew boiler is not heating all of the way to the set point, only > to around ~70C. The steam boiler heats up as it should and is working fine. > I switched the stock AKO temp controller to a generic temp controller to > see if that would solve the issue but nothing changed. The temp controller > still shows that it is calling for heat but for some reason the temp does > not go up even though the steam boiler is not on. > > Any ideas on what could be causing this issue? > > Thanks! > -- You received this message because you are subscribed to the Google Groups "Brewtus" group. To unsubscribe from this group and stop receiving emails from it, send an email to [email protected]. To post to this group, send email to [email protected]. Visit this group at http://groups.google.com/group/brewtus. For more options, visit https://groups.google.com/d/optout.